Feasibility Study on KSNP Adaption of French Digital Protection System

  • Published : 1996.08.01

Abstract

Upgrade of nuclear power plant I&C systems by using digital technology has been implemented to overcome the obsolescence of existing equipment and improve plant availability in many advanced countries. For upgrade of the Plant Protection System(PPS) based on conventional analog technology in the UCN 3&4 and YGN 5&6, French modernized Digital Integrated Protection System(DIPS) with proven technology is reviewed and evaluated for the adaptability into PPS. This paper contains the results of feasibility study for the design of digital PPS using French DIPS technology. Based on the results of evaluations, the system architecture of digital PPS is designed and described.

Keywords

References

  1. KAERI/IM-217/93 Feasibility Study for KSNP Adaptation of Advanced I & C System in the French Nuclear Power Plant
  2. N0291-SD-560 System Description of PPS For UGN 3 and 4
  3. Rev. C, IN/L-DC-0073 Dossier de Systeme Elementaire ; System de Protection de Reacteur
  4. Rev. B, May 93 Guide d'Exploitation et d'Entretien ; System de Protection Integre numerique
  5. Framatome, Presentation Material Advanced I&C System For Nuclear Power Plants A. Parry
  6. KAERI/AR-412/94 A Survey on the Development of Advanced Instrumentation and Control System in the Nuclear power Plant
  7. German Atom Forum Operating Experience of An Advanced Protection System On French 4 Loop Plants M. Bruyere
  8. Common-Mode/Common Cause Failure v.21 no.2 E. W. Hagent
  9. IEC Std. 880 Software for Computes in the Safety Systems of NPP
  10. IEEE Std. 7-4.3.2 Criteria For Digital Computers in Safety Systems of NPP
  11. Instrumentation and Control Digital systems : Reviews of Safety Critical Applications G. Ives
  12. Instrumentation and Control Digital Systems Ahead T. Albrigo Warning