Removal of Unburned-Carbon from Fly-Ash of Bituminous Coal by Froth Flotation

포말부유선광법에 의한 유연탄 비산회의 미연탄소분 제거연구

  • Published : 1996.09.01

Abstract

One of the most serious problems in utilizing the fly-ash produced from damcstic coal-firing power plants is lhc unburned-carbon mntained m the fly-ash In this shldy, the effects of fruther and collector an the yield,recuvery,unburnedcarbon rejectiou peiccntage,and process efficiency of product (cleaned fly-ash) wcrc examined when convzntional froth flotation was applied to rejcct the unburned-carbon included in the fly-ash of bituminous coal Alsa,the ash analysis for both thc raw and the clcaned fly-ash was conducted to review the change in thc major elements of fly-ash. Experimental results shawcd lhat tlle rcjectlon oI the unburned-cubon of thc raw fly-ash sample is available upto 92.4% using fiath flotalian and that the putity ol the pmdud(c1eancd fly-ash) attains up to 99.4%.

국내 석탄발전소에서 배출되고 있는 비산회의 재활용에 가장 큰 문제점은 비산화에 혼입되어 있는 미연탄소분이다. 본 연구는 기존 포말부유선광법으로 유연탄비산회의 미연탄소분을 제거할 때 기포제종류 및 첨가량의 영향, 포집제 첨가량의 영향을 실험하고, 여기에서 수율, 회수율, 미연분제거율, 공정효율을 구하였다. 또한 비산회정제 전후의 화학적 성분을 분석하여 성분변화를 확인하였다. 실험결과는 유연탄 비산회 중의 미연탄소분을 92.4%까지 제거할 수 있었으며, 그 결과 비산회의 순도를 99.4%까지 높일 수 있었다.

Keywords