Wind force coefficients of multi-span arched greenhouses with respect to wind direction of $0^{\circ}$ and $30^{\circ}$ were estimated to give more reasonable coefficient. The conventional and subdivided division types of wind force coefficient distribution diagrams were constructed by using the wind tunnel experimental data. Bending moments on the greenhouses were determined through structural analysis using obtained wind force coefficients, and were analyzed. Because actual wind pressure values on a face of greenhouse varied with locations, the more divisions of wind force coefficient distribution were subdivided, the better distribution type was coincided with actual state. In order to calculate the more accurate section force occurred on the arched greenhouse by the wind loads, it was recommendable that the wind force coefficient distribution should take more subdivision type. The maximum bending moment at the multi-span greenhouse frame at wind direction of $30^{\circ}$ was greater than that at O。, therefore the wind force coefficient at inclined wind direction to the wall was needed to be considered for the multi-span greenhouse structural design.

키워드

참고문헌

  1. ANSI 58.1 Minimum Design Loads for Buildings and Other Structures American National Standards Institute
  2. ASAE(R288.3) Designing building to resist snow and wind loads American Society of Agricultural Engineers
  3. The designer's guide to wind loading of building structres Cook,N.J.
  4. NEN 3859 Greenhouse structural requirements NGSI
  5. Wind effects on structures Simiu,E.;R.H.Scanlan
  6. 원예시설의 구조안전기준 작성(최종) 李錫建(外 15인)
  7. 韓國生物生産設計環境學會誌 v.4 no.1 아치형 單棟溫室의 最適設計를 위한 風力係數分布圖의 分析 李錫建;李賢雨;權武男
  8. 施設園藝 ハウスの設計と施工 立花一雄;羽倉弘人;高橋和彦
  9. 園藝用施設安全構造基準(暫定基準) 日本施設園藝協會
  10. 日本農業施設學會誌 v.23 no.1 ビニルハウスに作用する風荷重に關する硏究-風洞實驗による基礎的な風壓特性- 羽倉弘人;藤野宏道
  11. 日本農業施設學會誌 v.23 no.3 台灣における온실の自然換氣に關する硏究. -パイプハウスの換氣用風壓係數について- 黃 裕益(外 4인)