Journal of environmental and Sanitary engineering (환경위생공학)
- Volume 11 Issue 3
- /
- Pages.13-19
- /
- 1996
- /
- 2005-5889(pISSN)
Characteristics of Phenol Degradation in Wastewater Treatment using Packed bed reactor
충진층 반응기를 이용한 폐수처리에서 페놀의 분해 특성
Abstract
Packed bed reactor containing immobilized microorganisms which degraded phenol without growth was used to remove phenol from the synthetic wastewater. The effects of temperature, retention time(reactor volume/flow rate) and phenol concentration on the removal efficiency of phenol were investigated. The effect of temperature in the range of 20-30$\circ $C was negligible while retention time and phenol concentration influenced the removal of phenol significantly. When retention time was in the range of 1-1.5 hour, the removal efficiency of phenol was affected not by phenol concentration but by retention time itself while it was influenced by phenol concentration above 1.5 hour of retention time. The beads after 720 hours operation were swelled by 40 % in diameter which could be prevented by crosslinking with glutaraldehyde at the expense of cell activity.
Keywords