한국전문물리치료학회지 (Physical Therapy Korea)
- 제2권2호
- /
- Pages.46-55
- /
- 1995
- /
- 1225-8962(pISSN)
- /
- 2287-982X(eISSN)
주관절 가동범위 측정법에 대한 동시타당도와 신뢰도
Concurrent Validity, Inter-Tester and Intra-Tester Reliability of Goniometric Measurement of Active Elbow Range of Motion Using 4 Different Types of Measuring Instruments
- Current, Marion E. (Dept. of Rehabilitation, College of Health Science Yonsei University) ;
- Yi, Chung-Hwi (Dept. of Rehabilitation, College of Health Science Yonsei University)
- 발행 : 1995.12.09
초록
The purpose of this study was to assess the concurrent validity and reliability of goniometric measurement of joint motion. Subjects were 40 healthy university students. Measurements were performed by 4 inexperienced physical therapy students. Four different instruments were used and three readings were taken with each instrument in random order making a total of 12 readings for flexion of the right elbow of each subject. Goniometers used were 1. universal 2. fluid-based goniometer/inclinometer 3. digital LCD goniometer 4. electronic goniometer/torsiometer. The results were as follows: Concurrent validity was highest (r= .94) with the universal and digital LCD tools. Interrater reliability (Pearson Product Moment Correlation) was good for each tool. Interrater reliability calculated by ICC(2,1) was highest (.96) with the tensiometer and lowest (.78) with the digital LCD goniometer. Intrarater reliability calculated by ICC was excellent (