RCS Overpressure Protection Analysis Using SEBIM POSRV
SEBIM POSRV를 이용한 원자로 냉각재계통의 과압보호 해석
- Kim, Chong-Hoon (Korea Atomic Energy Research Institute) ;
- Seo, Jong-Tae (Korea Atomic Energy Research Institute)
- Published : 1995.04.01
Abstract
The overpressure protection system for PWR should be designed with sufficient capacity to limit the pressure to less than 110% of the reactor coolant system design pressure during the most severe abnormal operational transient. In this study, the feasibility of adopting the SEBIM POSRV instead of the current spring loaded pop-opening safety valves to the ABB-CE designed 2825 MWt PWR is investigated for its overpressure protection capability. The required SEBIM POSRV size as well as its opening/closing setpoints are determined through a series of computer analyses using the LTC code which has been used for the overpressure protection analysis for Yonggwang units 3&4. The analysis results show that the overpressure protection system with monobloc SEBIM POS-RV can maintain the RCS pressure below 110% of the design pressure demonstrating its overpressure protection capability for the ABB-CE designed 2825 MWt PWRs.
가압경수로의 과압보호계통은 가장 심각한 비정상 과도운전시 원자로냉각재계통의 압력을 설계압력의 110% 이내로 유지시킬 수 있는 충분한 용량으로 설계되어져야 한다. 본 연구에서는 ABB-CE 설계의 2825 MWt 가압경수로에 기존의 스프링 탑재형 가압기 안전밸브 대신 SEBIM-POSRV를 채택할 경우 과압보호 기능 수행의 가능성을 연구하였다. 과압보호 기능을 수행하기 위한 SEBIM POSRV의 크기 및 작동 설정치를 영광 3, 4호기의 과압보호 해석에 사용했던 LTC 전산코드를 이용한 분석을 통해서 결정했다. 분석 결과 monobloc SEBIM POSRV를 이용한 과압보호계통은 원자로냉각재계통의 압력을 설계 압력의 110% 이내로 유지시킴으로써 ABB-CE 형태의 2825 MWt급 가압경수로에서 과압보호 기능을 수행할 수 있음이 입증되었다.