Journal of the Korean Society of Groundwater Environment (대한지하수환경학회지)
- Volume 2 Issue 1
- /
- Pages.1-8
- /
- 1995
Groundwater Contamination at the Seokdae Waste Landfill Area of Pusan City
부산 석대 폐기물 매립장 일대의 지하수 오염
Abstract
Wastes produce groundwater contamination, offensive odor, and hazardous gases. This study investigates the contamination of groundwater at the Seokdae waste landfill area and seeks the desirable ways to minimize the groundwater contamination. Groundwater levels, water chemistry and aquifer characteristics of wells were examined around the Seokdae waste landfill. The water chemistry of the Dong stream, the groundwater distribution and flow were also studied. The results of this research show that the estimated quantity of the percolation from the landfill base to the ground is 520 ㎥/day and the extent of groundwater contamination is about 1-1.5 km from the center of the waste landfill. The groundwater contains heavy metals and other toxic elements. The conservation and management of the groundwater of the waste landfill need several monitoring wells to check the quantity and quality of groundwater, pumping wells to extract the contaminated groundwater, and slurry walls to protect the movement of contaminated groundwater.
매립장에서의 쓰레기는 주변 지역에 지하수오염, 악취, 유독가스 발생 등 큰 문제를 일으키고 있다. 본 연구에서는 최근에 부산시에서 만 6년 동안 사용해 왔었던 석대 폐기물 매립장 주변의 지하수 오염실태를 파악하고, 그 오염을 최소화할 수 있는 방안 연구를 목표로 매립장 주변의 우물과 시추공 내의 지하수위, 수질, 대수층 특성 등을 조사하고, 또 주변 하천의 수질, 매립장 일대의 지하수 분포 및 유동 상태 등을 연구하였다. 그 결과 지하로 침투하는 순수 침출수량은 일 평균 약 520 m
Keywords