Abstract
The vibration of reactor internals should be monitored and diagnosed for the early detection of the failure of reactor pressure vessel. This can be performed by analyzing the time-history signals from the excore neutron flux detertors. The conventional method is an on-demand system which generates power spectra through Fast Fourier Transform(FFT) algorithm. The operator can make his own decision to detect abnormal vibration using these spectra. This post- processing method, however, requires special expertise in the reactor noise analysis and signal processing for random data. It may mislead the operator into erroneous decision-making, if he is a novice in reactor noise analysis. Hence this study is focused on the automated monitoring and diagnosis procedure for the reactor noise analysis, especially on the Fuzzy algorithm to recognize the pattern of the vibration of Core Suport Barrel. The excore neutron signals of Yonggwang Nuclear Power Plant unit 3 is acquired and analyzed using conventional FFT spectra and tested to adopt the Fuzzy method. An Automated Monitoring and Diagnosis System for CSB Vibration using this Fuzzy method is proposed. Furthermore, vibration data for CSB of Youggwang Nnclear Power Plant unit 3 is presented.