Abstract
In this study, we investigated the operational limit of magnetic bearing-rotor system due to the maximum force limit and slew rjate limit of the electromagnetic actuator as a function of the time dependent control characteristics. The feedback gain of the controller varies the current of the electromagnet coil with the motion of the rotor. The distorsion of magnetic force due to the slew rate limit is not occurred jup to 30, 000 rpm in the magnetic bearing that we have a close relation with the rotational speed and vibration level of the rotor and the proportional gain of the controller. Therefore the maximum force limit determines the maximum allowable orbit radius of the magnetic bearing-rotor system. The maximum allowable vibration levels are exponentially decreased according to the increment of rotational speed and proportional gain of the controller.