Electrical Surveys for Mapping Leachate in Nanji - Do Landfill Site

난지도 일대의 침출수 양태 조사를 위한 전기 비저항 탐사

  • Published : 1995.12.01

Abstract

Electrical soundings and profilings were conducted for mapping the leachate in the region of Nanji - Do Landfill site. The results of electrical surveys conducted in the landfill area show that the basal leachate is formed at the height about 30 m above the mean sea level and that there is abundant floating leachate over the basal leachate. The surveys conducted around the landfill reveal that the groundwater which may be contaminated by the leachate from the landfill flows to the Han River. The top of the basement rock in this area has been severely affected by polluted groundwater. The layer which is thoroughly saturated with leachate in this region has the very low resistivity value below 10 ohm - m and this low resistivity value indicates that the groundwater and geology are severely contaminated by the leachate and wastes of the landfill.

난지도의 매립지 및 주변 침출수의 부존 양태를 파악하기 위하여 전기 비저항 수직 탐사와 수평 탄사가 수행되었다.매립지 내에서 수행된 전기 탐사 결과는 매립지 내에 기저 해발 고도 30m 지점을 전후로 하여 형성되어 있으며 이 기저 침출수 상부에도 상당량의 부유 침출수가 존재함을 보여준다. 매립지의 주변에서 획득된 전기 탐사 결과는 난지도의 침출수에 의해 오염된 지하수가 한강으로 유입되고 있음을 보여준다. 또한 이 지역의 기반암 상부도 이미 오염된 지하수에 크게 영향을 받는 것으로 판단된다. 난지도 매립지 및 주변 지역의, 침출수에 의해 포화된 지층은 전기 비저항치가 10 ohm-m 이하인 것으로 관측되었으며, 이러한 낮은 비저항치는 이 지역의 지하수 및 지층이 매우 심하게 오염되어있음을 지시한다.