Transactions of the Korean Society of Mechanical Engineers (대한기계학회논문집)
- Volume 19 Issue 9
- /
- Pages.2194-2205
- /
- 1995
- /
- 1225-5963(pISSN)
DOI QR Code
Output Behavior of Build-Up Force Measuring System
BUILD-UP 힘측정 시스템의 출력거동
Abstract
In order to reduce the systematic error of a build-up system, we have proposed a new test procedure in which all force transducers in a build-up system are rotated by 90.deg. with a base platen fixed on a force standard machine. The setting positions of force transducers on the output of a build-up system were investigated using an orthogonal array. The effects of the parallelism of a build-up system and of the bending moment sensitivity of a force transducer were considered. The experimental results show that the setting position of the base platen hardly affects the output of the build-up system, but the setting positions of force transducers affects it strongly. It reveals that the new test procedure reduces effectively the systematic error of a build-up system.
Keywords