Dosimetric Characteristics on Penumbra Regions of the Multileaf Collimator as Compared with the Lead Alloy Block
다엽 콜리메이터(Multileaf Collimator)와 합금납 차폐물(Lead Alloy Block)의 반 그림자영역의 선량 분포상의 특성 비교
- Lee Sang Wook (Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine) ;
- Oh Young Tack (Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine) ;
- Kim Woo Cheol (Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine) ;
- Keum Ki Chang (Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine) ;
- Yoon Seong Ick (Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine) ;
- Kim Hyun Soo (Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine) ;
- Park Won (Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine) ;
- Chu Seong Sil (Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine) ;
- Kim Gwi Eon (Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine)
- 이상욱 (연세대학교 의과대학 치료방사선과학교실, 연세 암센터) ;
- 오영택 (연세대학교 의과대학 치료방사선과학교실, 연세 암센터) ;
- 김우철 (연세대학교 의과대학 치료방사선과학교실, 연세 암센터) ;
- 금기창 (연세대학교 의과대학 치료방사선과학교실, 연세 암센터) ;
- 윤성익 (연세대학교 의과대학 치료방사선과학교실, 연세 암센터) ;
- 김현수 (연세대학교 의과대학 치료방사선과학교실, 연세 암센터) ;
- 박원 (연세대학교 의과대학 치료방사선과학교실, 연세 암센터) ;
- 추성실 (연세대학교 의과대학 치료방사선과학교실, 연세 암센터) ;
- 김귀언 (연세대학교 의과대학 치료방사선과학교실, 연세 암센터)
- Published : 1995.12.01
Abstract
Purpose : The Conformal Radiation Therapy has bee widely used under favour of development of computer technologies. The delivery of a large number of static radiation fields are being necessary for the conformal irradiation. In this paper we investigate dosimetric characteristics on penumbra regions of a multileaf collimator(MLC), and compare to those of lead alloy block for the optimal use of the system in 3-D conformal radiotherapy. Materials and Methods : The measurement of penumbra by MLC or lead alloy block was performed with 6 or 10 MV X-rays. The film was positioned at a dmax depth and 10 cm depth, and its optical density was determined using a scanning videodensitometer. The effective penumbra, the distance from
목적 : 컴퓨터의 발달에 힘입어 3-D Conformal Radiotherapy(3-D CRT)가 가능하게 되었고 3-D CRT를 위해서는 다엽콜리메이터(MLC)가 필수적인 장치이다. 이에 본 저자들은 MLC 사용시 반그림자(Penumbra)의 크기와 그 특성을 알아보고 기존의 합금납(lead alloy block)을 사용할 때의 반그림자와 차이를 비교 분석하여 임상에서 다엽콜리메이터(MLC)의 이용에 도움이 되고자 본 연구를 계획하였다. 방법 : MLC와 합금납의 반그림자를 측정하기 위해 6MV 와 10MV 에너지의 방사선을 이용하여 필름선량분석을 시행하였다. 필름에 각에너지의 dmax와 10cm 두께의 폴리스탈린 판톰을 올려 놓고 측정하였고, MLC의 종단면과 조사면의 y축과 이루는 각도를 변화시키면서 Effective penumbra(