DOI QR코드

DOI QR Code

The Flexural Behavior including Ductility of Half Precast Concrete Slab with Welded Deformed Wire Fabric

용접철망을 사용한 반두께 P.C.슬래브의 휨 및 연성거동

  • 이광수 (여주 전문대학 건축과) ;
  • 최종수 (한양대학교 건축공학과 석사과장) ;
  • 조민형 (벽산건설주식회사 상무) ;
  • 신성우 (한양대학교 건축공학과)
  • Published : 1994.08.01

Abstract

Ten Half precast concrete slabs reinforced with welded deformed wire fabric were tested under two concentrated loads to investigate the flexural moment and ductile capacity. The test variables were the compressive strength of topping concrete, quantitative roughness, and reinforcernent ratio. The effects of each test variables were studied separately. Test results were as followings. The ultimate strength design method is applicable to predict flexural strength for Half P.C. concrete slab with welded deformed wire fabric and quantitative roughness. It is proper to consider 0.0035 strain ;is yielding stress of the welded deformed wire fabric. The ductility index of Half precast concrete slab with welded deformed wire fabric showed lower value. Therefore to enhance the ductility capacity the normal defomed bar should be used with the welded deformed wire fabric for the longitudinal reinforcement.

본 연구는 용접철망을 사용한 반두께 프리캐스트 콘크리트 슬래브의 휨내력 평가 및 연성능력 검토를 위하여 총 10개의 일방향 반두께 프리캐스트 콘크리트 슬래브를 제작하여 2점 단순 재하를 하였다. 주요변수로서는 상부콘크리트 압축강도, 반두께 슬래브의 표면거칠기, 그리고 인장철근비로 구성되었으며, 실험결과는 다음과 같다. 반두께 프리캐스트 콘크리트 슬래브의 휨설계는 국내 극한강도 설계법에 의한 슬래브 설계방식의 사용이 가능한 것으로 나타났다. 슬래브에 $4000kg/cm^2$이상의 용접철망을 사용할 경우 기존의 규준에 따라 항복응력도를 변형율 0.0035에 해당하는 응력도를 사용하는 것이 안정적인 것으로 나타났다. 용접철망을 사용한 슬래브의 경우 철근 콘크리트 연성평가에 따라 분석한 결과 연성부담능력이 저하되어 용접철망을 경우에는 연성증진을 위한 일반철근을 혼용하는 것이 바람직한 것으로 판단된다.

Keywords