한국농공학회지 (Magazine of the Korean Society of Agricultural Engineers)
- 제36권3호
- /
- Pages.84-89
- /
- 1994
- /
- 0253-3146(pISSN)
원예시설의 지붕형식에 따른 단면력의 비교분석
Comparison of Maximum Section Forces of Greenhouse Structures with respect to Roof Types
초록
Section forces of greenhouse structures were studied to suggest basic information for the structural design of greenhouses with respect to roof types and support conditions. Structural analyses were performed for pitched and arched roof, and fixed and hinged support under snow loads and wind loads. Followings are the results obtained and are expected to be useful in determining the span length and roof type in greenhouse design. 1. Special considerations might he required for roof design at the heavy snow region, and for the support design at the strong wind region, respectively. 2. Single-span structure was found to be stronger than multi-span structure under the snow load, but the former was found to be weaker than the latter under the wind load. 3. Arched roof structure was expected to be safer than pitched roof structure if the dimensions and loads were equal. 4. Greenhouse orientation and roof slope should be considered in optimum structural design of grrenhouses, because these two factors are closely related with the influence of wind load and snow load.
키워드