Studies on Development of Microplate-EIA for the Determination of Serum Progesterone

혈청 Progesterone 측정을 위한 효소면역분석법 개발에 관한 연구

  • Published : 1994.02.01

Abstract

A simpled and sensitive microplate enzyme immunoassay(EIA) was developed for the determination of progesterone concentration in serum, based on progesterone monoclonal antibody as anti-progesterone, horseradish peroxidase(HRP) as enzyme-label and tetramethylbenzidine(TMB) as substrate. The assay has a sensitivity of 5 pg-120pg/well and intra- and inter-assay coefficients of variation for progesterone standard curve (1.0ng~10.0ng/ml) were ranged 2.5~9.9% and 1.7.8.0%, respectively, determination coefficient of the regressio equation of our standard curve(R2=0.990$\pm$0.007) were high, and this is the same level as that of commercial kit(Hormonost Bio-Lab, Germany, R2=0.98~0.99). The progesterone concentration of serum determined by both kits (Work & Bio-Lab) were significantly correlated (r=0.95, P<0.01) although a little higher value were resulted in our kit than that of commercial kit. It generally is these results indicated that the microplate-EIA can be cused for the determination of progesterone in serum, as well as, for the determination of the early pregnancy diagnosis.

Keywords