DOI QR코드

DOI QR Code

An Analysis of Flow Phenomena in Shock Tube System Design(I)-Comparison of Experimental and Computation Result-

충격파관 장치설계를 위한 유동현상의 해석(1)-계산치와 실험치의 비교-


Abstract

The shock tube is a useful device for investigating shock phenomena, spray combustion, unsteady gas dynamics, etc. Therefore, it is necessary to analyze exactly the flow phenomena in shock tube. In this study, the mechanics of its reflected shock zone has been investigated by using of the one-dimensional gas dynamic theory in order to estimate the transition from initial reflection of shock wave region. Calulation for four kinds of reflected shock tube temperature (i.e. (a) 1388 K (b) 1276 K (c) 1168 K (d) 1073 K) corresponding to the experimental conditions have been carried out sumarized as follows. (1) The qualitative tendency is almost the same as in that conditions in region of reflected wave region. (2) High temperature period (reflected shock wave temperature) $T_{5}$, exists 0-2.65 ms. (3) Transition period from temperature of reflection shock wave is far longer than the calculated one. This principally attributed to the fact that the contact surface is accelerated, also, due to the release of energy by viscoity effect. This apparatus can advance the ignition process of a spray in a ideal condition that involved neither atomization nor turbulent mixing process, where, using a shock tube, a column of droplets freely from atomizer was ignited behind a reflected shock.

Keywords