Journal of Periodontal and Implant Science
- Volume 23 Issue 3
- /
- Pages.493-506
- /
- 1993
- /
- 2093-2278(pISSN)
- /
- 2093-2286(eISSN)
EFFECT OF VARIOUS MECHANICAL TREATMENTS ON TITANIUM PLASMA SPRAYED IMPLANT SURFACES
Titanium plasma sprayed implant에 관한 여러가지 기계적 표면처리방법이 implant표면조도에 미치는 영향
- Yu, Hyeon-Seok (Department of Periodontology, College of Dentistry, Kyungpook National University) ;
- Park, Jae-Wan (Department of Periodontology, College of Dentistry, Kyungpook National University) ;
- Suh, Jo-Young (Department of Periodontology, College of Dentistry, Kyungpook National University)
- Published : 1993.11.30
Abstract
For maintenance of an ailing or failed implant it is essential to treat the implant fixture surface so as to remove bacterial endotoxin and make a surface tolerated by surrounding soft and hard tissue. Thus in this study the method that makes the smoothest surface treated with a high speed diamond bur, a low speed diamond bur, a stone, a rubber point or Jetpolisher was studied. With the profilomenter a mean value of
실패한 임프란트를 구강내에 유지하기 위하여는 임프란트 매식체의 표면을 처치하여 세균독소를 제거하구 주위의 연, 경조직에 적합한 표면 구조를 만들어 주어야 한다. 이에 본 연구에서는 임프란트 매식체 표면을 high speed diamond bur, low speed diamond bur, stone, rubber point, Jetpolisher로 처치하여 가장 평활한 표면을 만들 수 있는 방법을 알아 보았다. 조도측정기를 이용하여 표면의 최대높이값을 측정한 결과 high speed diamond bur, rubber point, Jetpolisher를 사용한 시편의 최대높이값의 평균은
Keywords