증기발생기 전열관의 균열성 결함에 대한 와전류 신호 평가

An Analysis of Eddy Current Signals for the Crack-like Defects in the Steam Generator Tubes

  • 발행 : 1993.05.31

초록

The steam generator tubes of the nuclear power plant should be inspected using eddy current techniques. Recently the crack-like defects become a major concern for the integrity of the steam generator tubes. These defects could be detected by the MRPC(Motorized Rotating Pancake Coil) method, not by the conventional bobbin coil method. In this paper it has been attempted to estimate the length of the cracks at the tube expansion region using of MRPC technique. The lengths of both axial and circumferential cracks show a tendency of overestimation compared to the real lengths. As the depths of the defects decrease from 100% through 50% of the wall thickness, the error of the length estimation is increased.

키워드