A Numerical Study of the 2-D Cold Flow for a Qubec City Stoker Incinerator

큐벡시 스토커 소각로 2차원 비반응 유동장 수치해석

  • Published : 1993.12.01

Abstract

A series of parametric investigations are performed in order to resolve the flow characteristic of a Quebec city stoker incinerator. The parameters considered in this study are five internal configurations of the Quebec city stoker itself and its modified ones, primary air velocity, the injection velocity and angle of the secondary air, and the reduction of the stoker exit area. A control-volume based finite-difference method by Patankar together with the power-law scheme is employed for discretization. The resolution of the pressure-velocity coupling is made by the use of SIMPLEC algorithm. The standard, two equation, k-$\varepsilon$ model is incorporated for the closure of turbulence. The size of recirculation region, turbulent viscosity, the mass fraction of the secondary air and pressure drop are calculated in order to analyze the characteristics of flow field. The results are physically acceptable and discussed in detail. The flow field of the Quebec city stoker shows the strong recirculation zone together with the high turbulence intensity over the upper part of the incinerator.

수치해석 방법에 의해 큐백시의 스토커 소각로 유동장을 분석하였다. 수치모사의 변수는 큐백시의 스토커 소각로를 중심으로 한 5가지 내부 형상, 1차공기 속도, 2차공기 속도 및 주입각, 출구면적을 고려하였다. 검사체적에 기초한 Patankar의 유한차분 방법을 사용한 본 논문에서는 power-law scheme과 SIMPLEC 알고리즘을 사용했으며 난류 유동은 표준 k-e 모델을 이용했다. 소각로 유동장 분석을 위해서 재순환 영역의 크기, 난류 점성계수 및 이차공기의 질량분율 분포, 압력강하를 계산했다. 계산 결과는 물리적 의미에 잘 맞게 나타났으며, 큐백시의 스토커 소각로가 다른 내부 형상의 소각로에 비해 상부에 강한 난류를 가진 재순환 영역을 형성하였다.

Keywords