Air-Water Flooding in Multirod Channels : Effects of Spacer Grids and Blockages

다봉채널내의 공기-물 플러딩 : 스페이서 그릿 및 블럭키지의 영향

  • Published : 1993.09.01

Abstract

This paper presents the experimental results on flooding of countercurrent flow in vertical multirod channels, which consists of falling water film and upward air flow. In particular, the effects of spacer grids, with and without mixing vane, and of blockage in the multirod bundle on the behaviour of flooding were investigated. The 5$\times$5 zircaloy tube bundle was used for the test section. The comparison of previous analytical models and empirical correlations with present data on flooding showed that the existing models and correlations predict much higher flooding curves. The spacer grid causes the lower flooding air flow rate to compare with the bare rod bundle. However, the mixing spacer grids need a higher flooding air flow rate for a constant liquid flow rate than the spacer grids without mixing vanes. The bundle containing blockages has the highest flooding air flow rate among the bundles with spacer grids and blockages. Empirical flooding correlations for the three types of test section have been made.

이 논문은 하강하는 물의 막과 상승하는 공기유동으로 구성된 수직 다봉채널내서의 역유동 플러딩에 관한 실험결과를 발표한 것이다. 특히 다봉속에 혼합깃이 있는 것과 없는 스페이서 그릿 및 블럭키지가 프러딩의 거동에 미치는 영향이 조사되었다. 시험부에는 5$\times$5 지르칼로이관속이 사용되었다. 플러딩에 관한 전의 해석적 모델과 실험적 상관식들을 본 실험결과와 비교한즉 기존의 모델과 상관식들이 매우 높은 플러딩 곡선을 예측함이 발혀졌다. 스페이서 그릿은 이것이 없는 봉속과 비교하면 낮은 플러딩 공기유량을 나타낸다. 그러나 혼합깃이 있는 스페이서 그릿은 이것이 없는 스페이서 그릿에 비하여 높은 플러딩 공기유량이 요구된다. 블럭키지를 가진 봉속은 더욱더 높은 플러딩 공기유량을 갖는다. 세가지 형식의 시험봉 속에 대한 실험적 플러딩 상관식이 얻어졌다.

Keywords