Application of Soil Factor on the Aseismic Design

내진 설계시 지반계수의 합리적 적용에 대한 연구

  • 이인모 (정회원, 고려대학교 공과대학 토목환경공학과) ;
  • 임종석 (동아엔지니어링 지반사업부, 정회원 대한주택공사 주택연구소 선임연구원 정회원, 대한주택공사 주택연구소 연구원)
  • Published : 1993.03.01

Abstract

The first Korean earthquake resistant design code was enacted in 1988. In the code, the soil factor which takes into account both the soil amplification factor and the soil -structare interaction effect is divided into three groups : soil factor, 5 : 1.0, 1.2 and 1.5. In order to assist in choosing the soil factors appropriately in the earthquake resistant design, the local site effects on the based shear force induced by earthquakes are considered in depth for typical soil conditions in Korea. The depth of the alluvial and/or weathered zone is usually not deep and the fresh rock is found at depth shallower than 20 meters, and even at about 10 meters around Seoul. One dimensional wave propagation theory and the elastic half space method are used to obtain the soil -structure interaction effect as well as the soil amplification effect. The kinematic interaction effect due to scattering of waves by pile foundation is also considered. Finally, the soil factor is recommended for each soil condition from loose state to dense, and also from shallow soil depth to deep, so that the designer can choose the factor with-out difficulty.

1988년 건설부에서 제정한 건축물에 대한 재진설계규준'에는 저면 전단력 산정시 지반계수가 1.0, 1.2, 1.5로 구분되어 있는데, 특히 얕은지반의 연약층에서 지반계수의 선정이 모호할 때가 많다. 또한 우리나라의 지반특성은 대부분 퐁화암 및 연암층이 20m이내에서 발견됨을 고려하여, 일차원 파전파 이론과 반무한 탄성이론 및 문헌을 통한 분석을 통해 지진 하중시 지반의 조건이 저면 전단력에 미치는 증폭효과를 비교분석하여 내진 설계시 적절한 지반계수 선택을 할 수 있도록 하였다.

Keywords