Abstract
The suspended particulate matters had been collected by a cascade impactor having 9 size fragnated stages for 2 years (Dec. 1989 to Nov. 1991) in Kyung Hee University-Suwon Campus. The particulate matters were then collected on each stage by membrane filters. The weight concentration on each stage was estimated by a microbalance and further chemical element concentrations were determined by an XRF system. The study focused on developing of a receptor model using the TTFA (target transformation factor analysis) to apportion aerosol mass with the 30 ambient data sets. Each data set consists of the 8 size-ranged subdata sets characterized by 13 element variables. Even though a couple of sources could not be identified, three to five sources were extracted from each aerosol size-range, and then 9 statistical source profiles were generated. Finally, source contribution of particulate matters on each size-range could be estimated in Suwon area.