Abstract
Recently a passive $NO_2$ samplers have been frequently used for the measurement of $NO_2$ concentration in the atmosphere because of its simplicity and high accuracy. But these samplers have a defect that the amount of $NO_2$ adsorbed is increased by wind. In this study, the inlet of sampler was covered with a draft shield made by 325 mesh stainless sieve to eliminate the effect. But it was expected that $NO_2$ diffusion was interrupted by the draft shield. In order to conform this phenomenon, samplers with and without draft shield were exposed to a box filled with 1-1.1ppm $NO_2$. The result indicated that draft shield nearly did not disturb $NO_2$ diffusion. To protect samplers from dust, sunshine, precipitation and vertical wind effects, these samplers were placed into a shelter during the field test. The data obtained in this study was compared with the data from the ambient air monitoring network. The coefficient of correlation(r) between the two data was 0.9995 for the test period of up to 35days. The results of this study indicate that the type of $NO_2$ samplers with draft shield in shelter used in this study can be used for measuring $NO_2$ concentrations in the ambient air relatively for a long period over 30 days.