Study on Effective Treatment of Waste Gases in Chung-Ju Industrial Complex with Polymeric Absorbent( I )

고분자담지제에 의한 청주공단내 공장배기가스의 효율적 처리기술대책에 관한 연구(I) -청주공장내 공장배기가스 조사 및 분석을 중심으로-

  • 이상혁 (한국교원대학교 기술교육학과) ;
  • 이영순 (서울산업대학 산업안전공학과) ;
  • 전종한 (대전공업대학 공업화학과)
  • Published : 1992.06.01

Abstract

The exhausted gases were analyzed and the countermeasures were studied to solve the environmental pollution caused by waste gases in Chung-Ju Industral Complex. The eleven working places were selected to analysis the compositions and concentrations of the exhausted gases by gas chromatograph and membrane method. The five companies which have used organic solvents were shown lower content than TLV and the environmental limits. But the concentration of lead in a electric product company was revealed higher than TLV. The waste gases of the four companies which have used asbestos were shown lower values than TLV and the environmental limit. The exhausted gases, SO$_2$and NO$_2$of two companies which have used fossile fuels were also analyzed. The NO$_2$concentration of one company which haven't disposal system was shown higher than the environmental limit.

Keywords