A Study on Cross Type Heat Exchanger Using Element Method

직교류형 열교환기에 대한 엘리멘트를 이용한 열정산 방법에 관한 연구

  • 정형호 (한국과학기술연구원 공조.환경제어연구실) ;
  • 신흥태 (한국과학기술연구원 공조.환경제어연구실) ;
  • 김광호 (한국과학기술연구원 터보기계연구실) ;
  • 이춘식 (한국과학기술연구원 공조.환경제어연구실)
  • Published : 1991.05.01

Abstract

A thermal analysis method taking into account energy balance in each elements of heat exchanger was introduced. This method has a merit in predicting the temperature field over the heat exchanger in detail. To verify this method, the results were compared with the published ones. The thermal analysis of the radiator in vehicles was also conducted and the results were compared with experimental ones. It is concluded that this method can be used in thermal analysis with relatively small error. When the velocity profile of inlet air is not uniform, the outlet temperature of cooling water is higher than that of uniform velocity profile.