Abstract
The elution characteristics of rare earth elements in $NH^{4+}$ form cation exchange resin had been investigated. Elution were performed varing the loading amount, column diameter, column length and eluent pH. Analysing the chemical species contained in each effluent, elution mechanisms of rare earth elements and the separation of rare earth elements in monazite could be understood. The resolution values of adjacent rare earth elements were improved increasing rare earths adsorption amount wfith the same column within it's exchange capacity. With $NH^{4+}$ resin form, column length does not affect on the resolution values and retention time of rare earth elements and the rare earth-EDTA complex were not adsorbed on $NH^{4+}$ resin form. pH of eluent affected on the reactivities between rare earth elements and EDTA. Decreasing eluent pH, resolution values of adjacent rare earth elements were increased while increasing elution time.
$NH^{4+}$ retaining 이온으로 치환된 양이온교환 수지관에서 흡착시키는 희토류원소이온의 양, 수지관의 내경, 수지관의 길이 및 용리액의 pH 등을 변화시켜 용리시킨 후 용출액 중의 각 화학종을 분석하여 희토류원소이온의 용리 mechanism과 monazite 광에 포함된 희토류원소들의 분리에 관해 연구하였다. 인접한 희토류원소간의 분리능은 수지의 교환용량 이내에서는 흡착시키는 희토류원소이온의 양을 증가시킬수록 증가하였고, 내경이 같으면 수지관의 높이는 희토류원소이온의 분리능 및 분리시간에 영향을 미치지 않으며 희토류-EDTA 착물은 $NH^{4+}$형 수지에 흡착되지 않음을 알 수 있었다. 용리액의 pH는 수지관 내에서 희토류원소이온과 EDTA와의 반응성에 영향을 미쳐 분리에 큰 영향을 미쳤으며 pH가 낮을수록 분리능은 향상되나 분리시간이 길어짐을 알 수 있었다.