A Clinical Study on the Electric Pulp Test
전기적 치수자극 평가법에 대한 임상적 연구
- Dae-Geun Yoon (Dept. of Oral Diagtnosis and Oral Medicine School of Dentistry, Chosun University) ;
- Chang-Lyuk Yoon (Dept. of Oral Diagtnosis and Oral Medicine School of Dentistry, Chosun University)
- Published : 1991.06.01
Abstract
The purpose of this study carried into the Electric pulp test for having knowledge of the difference of each one's stimulant threshold in normal teeth, the stimulant threshold at 10:00 A.M. and 3:00 P.M. in the same teeth, the differendce of the stimulant threshold between dental caries and normal contralateral teeth. In this study, 27 students aged between 22 and 24 years were selected from a pool of students who are sttending school of dentistry, chosun university who did not possessed dental disease like the dental caries, periodontal disease and restoration etc., and 30 outpatients who possessed dental caries(++). The obtained results were as follows : 1. The stimulant thresholds of the premolars and canine were higher than that of the incisors. 2. The stimulant thresholds of the carious teeth were lower than that normal contralateral teeth. 3. There were no difference stimulant threshold at 10:00 A.M. and 3:00 P.M.