PC-Based Random Neutron Process Measurement in a Thermal Reactor

PC에 의한 열중성자로 중성자의 무작위 특성 측정

  • Published : 1990.03.01

Abstract

A PC-based system for measuring and analysing random neutron process in the thermal reactor is developed and applied to TRIGA Mark-II reactor at KAERI. It is confirmed that this system has several advantages compared to conventional methods. So far, two techniques, autocorrelation and variance to mean ratio (VTMR), have been applied for analysing the count data collected from the single detector by using this system. The results of the two techniques agree within acceptable difference, but VTMR's results show much superior statistical reliability than those of autocorrelation especially when it is near critical. The $\beta$/Λ of TRIGA Mark-II reactor is measured to be about 125/sec when the reactivity is within -3$ and about 150/sec when it is below -4$.

열중성자로의 무작위 중성자 특성을 PC로써 측정하는 체계를 개발하고 이를 한국에너지연구소의 TRIGA Mark-II 원자로에 응용하였다. 그 결과 이 체계는 재래의 여러 방법에 비하여 많은 장점을 가지고 있음을 확인하였다. 아직은 한개의 계측기를 사용하였고, 즉발중성자만 고려한 시간 영역에 대하여 autocorrelation과 VTMR 두가지 방법으로 분석하였다. 두 방법의 결과는 서로 잘 일치하였으나 통계적인 신뢰도 면에서는 VTMR이 훨씬 나았고, 특히 임계 근처에서 이것이 두드러졌다. TRIGA Mark-II의 $\beta$/Λ 는 임계에서 -3$까지는 약 125/초, -4$이하에서는 약 150/초로 측정되었다.

Keywords