Assessment of RELAP5/MOD2 Code using Loss of Offsite Power Transient of Kori Unit 1

고리 1호기 외부 전원 상실사고에 의한 RELAP5/MOD2코드 모델 평가

  • Published : 1990.03.01

Abstract

The Loss of Offsite Power Transient at 77.5% power which occurred on June 9, 1981 at the Kori Unit 1 PWR (Pressurized Water Reactor) is simulated using the RELAP5/MOD2 system thermal-hydraulics computer code. Major thermal-hydraulic parameters are compared with the available plant data. The comparison of the analysis results with the plant data demonstrates that the RELAP5/MOD2 code has the capability to simulate the thermal-hydraulic behaviour of PWRs under accident conditions of this type with accuracy, except the pressurizer pressure and level. The pressurizer pressure increase is sensitive to the in surge now it is believed that the interracial heat transfer in a horizontal stratified flow regime may be estimated low and the compression effect due to insurge flow may be high. In the nodalization sensitivity study it is found that S/G noding with junctions between bypass plenum and steam dome is preferred to simulate the S/G water level decreasing and avoid the spurious level peak at trubine trip.

1981년 6월 9일 고리 1호기 원자력발전소에서 발생한 외부 전원 상실사고 자료를 근거로 RELAP5/MOD2코드모델 평가를 하였다. 계산된 주요 열ㆍ수력학 변수를 실측자료와 비교 분석하였으며 증기발생기의 Nodalization 민감도 분석이 수행되었다. 계산된 열ㆍ수력학 변수는 실측치와 비교적 잘 일치하고 있으며, 이러한 유형의 사고 분석에 RELAP5/MOD2가 적합하다는 것을 보였다. 그러나 가압기 압력과 수위변동에서는 상당한 차이를 보였으며 높게 계산되었다. 이러한 사실은 RELAP5의 수직관에서의 층류 열전달 모델에 기인하는 것으로 해당모델의 개선을 요하고 있다는 것을 알았다. 그리고 증기발생기의 Nodalization 연구를 통하여 수위변동을 잘 예측하기 1위해서는 증기발생기 증기 Dome와 Downcomer사이에 압력을 전달시켜주는 유로를 모델링 하여야 한다는 것을 알았다.