Temperature Variation during Construction in the Concrete Dam Body by Artificial Cooling

강제냉각(强制冷却)에 의한 콘크리트 제체(堤體)의 시공중(施工中) 온도변동(溫度變動)

  • 이배호 (중앙대학교 공과대학 토목공학과) ;
  • 김홍철 (서울산업대학 토목공학과)
  • Received : 1989.06.12
  • Published : 1989.09.30

Abstract

The concrete temperature in mass concrete rises rapidly above the placing temperature owing to the heat given off by the hydrating cement. This temperature rise produces tensile stress and cracks which later become the cause of water leakage in concrete structures. It is essential, therefore, to reduce the interior heat of concrete dam given off by hydrating cement by artificial cooling. The present study aiming to study the temperature variations in mass concrete by pipe cooling, compars the actual measurements of Chungju Dam with the temperature calculated by Finite Difference Method(FDM), and it found that the results closely agree with each other. Based on these results, the analyses are performed simulate the interior temperature history of concerte dam made of type II (moderate heat) portland cement under various coditions.

매스콘크리트(mass concrete)는 시멘트의 수화숙(水和熟)에 의하여 온도응력(溫度應力)이 생기며, 균열(龜裂)을 일으키게 된다. 매스콘크리트 내부(內部) 온도(溫度) 해석(解析)에는 Carlson의 방법(方法)이나, Glover의 방법(方法) 등이 오늘날까지 많이 쓰여 왔으나 이 방법(方法)들은 공학적(工學的)으로 간단한 가정(假定)을 하여 온도(溫度) 해석(解析)하고 있으므로, 실체적인 추정치(推定値)가 되지 못 한다고 알려져 있다. 본(本) 연구(硏究)에서는 유한차분법(有限差分法)(FDM)에 의하여 콘크리트 댐의 내부온도(內部溫度)를 해석(解析)하고, 이것의 유용성(有用性)을 검토(檢討)하기 위하여 계산기(計算機)로 계산한 계산치(計算値)와 충주(忠州) 대에서 실측(實測)한 실측치(實測値)를 비교검토(比較檢討)한 결과 좋은 근사치(近似値)를 얻었다.

Keywords