Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (I). Continuous-Automated Determination of Nitrite Ion Using Tubular PVC Membrane Type of pH Electrode

용해기체 분석용 기체 감응막 이온선택성 전극 (제 1 보). 관형 PVC 막 pH 전극을 이용한 아질산이온의 연속·자동화 정량

  • Heung Lark Lee (Department of Chemistry, Kyungpook National University) ;
  • Jong Hoon Yun (Environmental Science Institute, Kyungpook National University)
  • 이흥락 (경북대학교 자연과학대학 화학과) ;
  • 윤종훈 (경북대학교 환경과학연구소)
  • Published : 1989.08.20

Abstract

A continuous-automated method for the determination of nitrite ion using gas-sensing membrane electrode was developed. The pH electrode of tubular PVC membrane type was used as a detector of this system. The slope of linear response of the electrode measured at optimum conditions for the continuous-automated determination of nitrite ion was 63.5 mV/decade. The concentration range of linear response and detection limit were 2.5 ${\times}10^{-4}{\sim}\;7.5{\times}10^{-2}$M and $8.0{\times}10^{-5}$M, respectively. This detection system was not only less interfering to acidic gas species than other methods but also less time consumable for determination.

기체 감응막전극을 이용하여 수용액 중의 아질산이온을 연속${\cdot}$자동화법으로 정량하는 방법을 개발하였다. 이 방법에서 최종검출기로 쓴 이온선택성 전극은 관형 PVC막 pH 전극이었다. 장치계의 최적조건에서 구한 아질산이온 표준시료에 대한 전극의 감응기울기는 63.5mV/decade 이었으며, 직선감응 범위는 $2.5{\times}10^{-4}\; M{\sim}7.5 {\times} $10^{-2}$M 이었고, 검출한계는 $8.0{\times} 10^{-5}$M이었다. 이 방법은 다른 정량법보다 산성기체종의 방해를 적게 받을 뿐만 아니라 정량에 필요한 시간도 훨씬 단축할 수 있었다.

Keywords

References

  1. Analyst v.95 D. R. Keeney;B. H. B. Byrnes;J. J. Genson
  2. Anal. Chem. v.42 R. D. Martini
  3. Anal. Chim. Acta v.60 G. P. Morie;J. Ledford;C. A. Glover
  4. Anal. Chem. v.45 B. M. Kneebone;H. Freiser
  5. Bunseki Kagaku v.29 K. Suzuki;H. Ishiwada;T. Shirai;S. Yanagisawa
  6. Bunseki Kagaku v.30 K. Suzuki;H. Ishiwada;K. Saito;T. Shirai
  7. 한국대기보전학회지 v.1 이용근;김창규;박정태;김경섭;황규자
  8. Pure Appl. Chem. v.36 J. W. Ross;J. H. Risemann;J. A. Krruger
  9. Analyst v.100 P.L.Bailey;M. Riley
  10. La Chimica et L'industria v.62 M. Mascini;C. Cremishini
  11. Anal. Chim. Acta v.77 M. Mascini;C. Cremishini
  12. Comm. In Soil Science and Plant Analysis v.5 no.6 M. A. Tabatabai
  13. JAOAC v.59 S. Sherken
  14. Anal. Chim. Acta v.128 F. Castellani;V. Bartocci;M. Gusteri;F. Pucciarelli
  15. Anal. Chim. Acta v.128 F. Castellani;V. Bartocci;M. Gusteri;F. Pucciarelli
  16. Anal. Chem. v.52 M. E. Meyerhoff
  17. Anal. Chem. v.53 Y. M. Fraticelli;M. E. Meyerhoff
  18. Anal. Chim. Acta v.155 W. N. Opdycke;S. J. Parks;M. E. Meyerhoff
  19. Analyst v.110 H. L. Lee;M. E. Meyerhoff
  20. Analyst v.28 M. E. Meyerhoff;Y.M.Fraticelli;J. A. Greenberg;J. Rosen;S. J. Parks;W. N. Opdycke
  21. Anal. Chem. v.46 P. V. Winkel;J. Mertens;D. L. Massart
  22. Anal. Chem. v.42 B. Fleet;G. A. Rechnitz
  23. Anal. Chim. Acta v.131 P. Schulthess;Y. Shijo;H. V. Phan;E. Pretsch;D. Ammann;W. Simon
  24. Pure Appl. Chem. v.48 Recommendations for Nomenclature of Ion-Selective Electrodes IUPAC
  25. Advances in Environmental Sciences and Engineering, Vol. 4, Gorden and Breach Sciences Solubility Equilibria of the Nitrogen Oxides and Oxyacids in Dilute Aqueous Solution S. E. Schwarch;W. H. White
  26. Anal. Lett. v.10 R. A. Durst
  27. Anal. Chem. v.57 S. S. M. Hassan;F. A. Tadros