유압원격제어를 위한 덤프와 감압밸브의 특성에 관한 연구

A Study on Characteristics of Dump and Reducing Valve for Hydraulic Remote Control System

  • 오철환 (서울교육대학 실과) ;
  • 김광 (패시픽 컨트롤(주)) ;
  • 송창섭 (한양대학교 정밀기계공학과)
  • 발행 : 1988.09.01

초록

In recent, the requirement of remote control of hychaulic system is in- creasing. The actuator unit whose output position is proportional to input electrical signal needs a pressure reducer and a dump valve. The pressure reducer provides a constant regulated pressure and filters contaminants. The dump valve supplies proper pressure to the pressure reducer and unloads when the system is not operated. In this thesis, dump valve and pressure reducer with auxiliary function are studied. The choke in the pressure reducer prevents actuator from supplying higher pressure than necessary pressure at beginning, and the spring constant affects on the dynamic characterisics. In dump valve, it is proved that diameter of servo-slide hold and choke diameter of dump plunger affects on damping response.

키워드