Journal of Chest Surgery
- Volume 21 Issue 2
- /
- Pages.223-230
- /
- 1988
- /
- 2765-1606(pISSN)
- /
- 2765-1614(eISSN)
In Vivo Estimation of Emax and Ejection Fraction Using Dynamic Spatial Reconstructor
역동적 삼차원 재구성기로 측정한 In Vivo 상태의 좌심실의 Emax 와 박출계수
Abstract
Emax, end-systolic pressure-volume relationship, has been established as a new concept which can be representative of ventricular contractility itself since 1970s. Comparing to ejection fraction[EF], Emax is independent of preload and afterload. However Emax has not been proved precisely in non-thoracotomized condition because current methods have limitation in measuring ventricular chamber volume accurately in in viva state. The Dynamic Spatial Reconstructor[DSR], high speed computerized tomography, can measure ventricular chamber volume accurately throughout cardiac cycle in non-thoracotomized state. So Emax and EF of the left ventricle was tried to measure precisely in in vivo condition with DSR. Emax was compared to EF to estimate its ability to evaluate ventricular contractility. 5 mongrel dogs, weighing 15-16kg, were used for measuring Emax and EF of the left ventricle in 3 or 4 different loading conditions using DSR. Emax value in 5 dogs was from 2.62 to 10.49. Each dog has one Emax value regardless of loading conditions. However EF in 5 dogs varies depending on loading conditions. The conclusions are that Emax is useful in in viva state and EF varies depending on loading conditions. So Emax should be tried to use in clinical situation rather than EF because it is always representative of contractility itself regardless loading conditions in in viva state.
Keywords