Optimal Switching Pattern of Voltage Source Inverter

전압원인버어터의 최적스위칭패턴

  • Published : 1987.08.01

Abstract

This paper is proposed the Suboptimal PAWM(Pulse Amplitude Width Modulation) for minimize harmonic effects generated by switching operation of PWM Inverter. This strategy determine one switching pattern at a fixed point(fundamental) voltage u1=1.2) which THD(Total Harmonic Distortion) are minimized in the suboptimal PWM strategy, and controls only frequency in the inverter while voltage control is carried out by DC Chopper in the DC Link. This strategy is applied at VSD(Variable Speed Drive) of Three phase induction moter, and acoustic noise of motor, line to line voltage and current of inverter, current harmonic spectrum was estimated and also compared with other switching strategy. From the results, the validity of this strategy can be verified.

本 論文은 PWM(Pulse Width Modulation)인버어터의 스위칭作用에 의해서 發生하는 高周波 影響을 最小化하기 위한 Suboptimal PAWM(Pulse Amplitude Width Modulation)을 提示하였다. 本 方式은 Suboptimal PWM에서 THD(Total Harmonic Distorition)가 最小가 되는 固定點(基本波 電壓 u1=1.2)에서 하나의 스위칭패턴을 決定하였다. 그리고 電壓은 DC Link에서 DC Chopper에 의해 制御하게 하고 인버어터에서는 단지 高周波만을 制御하도록 하였다. 本 方式은 3相 誘導電動機의 VSD(Variable Speed Drive)에 適用하여 電動機의 騷音, 인버어터의 線間電壓 및 電流, 電流高周波 스펙트럼을 測定하였으며, 他 方式과 比較해 보았다. 그 結果로부터 本 方式의 妥當性을 立證할 수 있었다.