RECOVERY OF FREOU-11 USED IN A PROCESSING SYSTEM OF TOBACCO EXPANSION (ABOUT COOLING AND COMPRESSION SYSTEM)

담배 팽화공정에 사용된 Freon-11의 회수 (냉각 및 압축 system에 관해서)

  • 김기환 (한국인삼연초연구소 제품개발부 제 4실) ;
  • 유광근 (한국인삼연초연구소 제품개발부 제 4실) ;
  • 주영석 (한국인삼연초연구소 제품개발부 제 4실) ;
  • 최영현 (한국인삼연초연구소 제품개발부 제 4실) ;
  • 김병구 (한국인삼연초연구소 제품개발부 제 4실)
  • Published : 1985.11.01

Abstract

The purpose of this study is to improve the method and the apparatus for recovering freon-11 used in a process for increasing the filling capacity of tobacco. The first, the theoretical recovery rate of freon-11 was calculated from vapour pressure and thermodynamic properties of freon-11. The second, the usability of theoretical data was evaluated by the comparison between the theoretical data and the experimental data from the pilot plant. The result obtained under the present experiment condition was quite similar to the rate at 15kg/cm2 and 5$^{\circ}C$, but the theoretical data evaluated were 0.1 to 0.3% lower than the experimental data at 20 to 25kg/cm2 and 5$^{\circ}C$. The recovery rate of the cooling and the compression system was about 95% with freon-11 used in this system and that with freon-11 concentrate of waste gas was about 3 to 3.6% at 20 to 25kg/cm2 and 5$^{\circ}C$.