Abstract

An alternative estimator for dose equivalent was derived. The original LET distribution concept was transformed into a charged particle fluence spectrum concept along with the definition of an average quality factor named slowing-down averaged quality factor by adopting the continuous slowing down approximation. With the alternative estimator, the dose equivalent delivered into a receptor located in a given radiation field can be directly and conveniently estimated in a Monte Carlo procedure. The slowing-down averaged quality factors for the energy range below 10 MeV were evaluated and tabulated for the charged particles which may be generated from the interactions of neutron with the nuclei composing soft tissue.

연속감속근사법(CSDA)과 감속평균선질계수를 이용하여 선량당량 정의에서의 본래의 LET분포 개념을 하전입자속 스펙트럼의 개념으로 변환함으로써 새로운 선량당량 산정법을 도출하였다. 이 산정법을 몬테칼로법에 적용함으로써 주어진 방사선장에 위치한 피사체 내에서의 선량당량을 직접적으로 간편하게 산출할 수 있다. 산정에 필요한 감속평균 선질계수는 중성자와 연조직과의 상호작용으로부터 발생될 수 있는 모든 하전입자에 대하여 10 MeV 이하의 에너지 범위에서 산출하여 제시하였다.

Keywords