Design and Performance of the Modified Hydrometer for the Rapid Measurement of Clay Content in Soils

점토함량(粘土含量) 간이측정기(簡易測定器) 개발연구(開發硏究)

  • Jo, I.S. (Institute of Agricultural Sciences, ORD) ;
  • Kim, L.Y. (Institute of Agricultural Sciences, ORD) ;
  • Ryu, K.S. (Institute of Agricultural Sciences, ORD) ;
  • Im, J.N. (Institute of Agricultural Sciences, ORD) ;
  • Um, K.T. (Institute of Agricultural Sciences, ORD) ;
  • Kwag, Y.S. (Institute of Agricultural Sciences, ORD)
  • Published : 1984.12.25

Abstract

This study was conducted to evaluate the performance of a miniaturized hydrometer of clay content determination in the field. The performance of the miniaturized hydrometer was compared to that of 152H hydrometer and pipette methods. Statistical analysis of the results showed the possibility of using the miniaturized hydrometer for clay content determination in the field.

객토원(客土源)과 객토대상지(客土對象地)의 판정(判定)에 필수적(必須的)인 점토함량(粘土含量) 측정(測定)의 간이화(簡易化)를 위한 새로운 간이기기(簡易器機)를 개발(開發)코자 Hydrometer의 소형화(小型化)에 초점(焦點)을 두고 새로운 기기(器機)를 제작(製作)하여 기존(旣存) Pipette법(法)과 비교(比較)한 결과(結果)는 다음과 같다. 1. 길이가 16cm, 눈금범위(範圍)가 0~45%인 Hydrometer와 10g채취용(採取用) 간이토양시료(簡易土壤試料) 채취용기(採取容器)가 설계(設計) 제작(製作)되었다. 2. 간이기기(簡易器機)는 유효(有效)길이 (측정깊이)가 적어서 152H Hydrometer 보다 같은 시간(時間)에 훨씬 적은 입자(粒子)의 함량(含量)을 측정(測定)할 수 있었다. 3. 입제(粒劑) 분산제(分散劑)를 용해(溶解)시키고 시료(試料)를 넣은 후 2분간(分間) 강(强)하게 진탕(振蕩)한 후 10분(分)만에 측정(測定)된 값은 Pipette법(法)에 의한 토양(土壤)의 점토함량(粘土含量)과 비교(比較)한 결과(結果) t=0.573 < t 0.05=1.98로서 두 방법간(方法間)에는 차이(差異)가 없었다.

Keywords