Abstract
The single crystal ion-selective electrode,$ {\beta}-Ag_3SI/PVC-THF $membrane electrode has showed a linear potential response to the activities of iodide ion (10-1${\sim}$10-7M). The $ {\beta}-Ag_3SI$ membrane electrode was compared with AgI/PVC-THF membrane and copper metal plate membrane electrodes. In order to measure the selectivity coefficient of the electrodes toward $Cl^-$ and $Br^-$, the separation and mixed solution method were employed. The potential-time curve was obtained by the usual immersion technique and pH effect was also examined. The orders of selectivity for $Br^-$, $Cl^-$ and stability of response time are ${\beta}-Ag_3SI/PVC-THF $membrane > AgI/PVC-THF membrane > copper metal plate membrane. These electrodes could be used as indicating electrodes in the potentiometric titration of a single halide and mixed halides with the standard solution of silver nitrate.
${\beta}-Ag_3SI$의 단결정을 만들어 막전극으로의 응용을 살펴보았다. 그 결과 할로겐 이온들에 대해 감응함을 알았고, 분리용액법과 혼합용액법으로 할로겐 이온들에 대한 선택계수를 얻어 이론값과 비교검토 하였으며, 전위시간 곡선으로 부터 이 전극이 유리 전극기구에 의해 전도함을 알았고, 넓은 pH 범위에서 전위가 일정한 값을 가짐을 알았다. 한편 분석화학에의 응용을 살펴 본 결과 할로겐이온의 혼합용액에서 좋은 지시전극으로 사용할 수 있음을 알았다