Esophageal manometry in the patients with foreign body sensation on the pharyngo-esopgageal region

인두 및 상부식도부 이물감 환자의 식도내

  • Published : 1984.06.01

Abstract

Although it is suspected that the foreign body sensation on the pharyngoesophageal region is caused by motility disturbance of upper esophageal sphincter, its pathophysiology is not yet clear. Esophageal manometry has become an important diagnostic tool in the evaluation of esophageal motor disorders such as dysfunction of upper esophageal sphincter. Intraluminal esophageal pressures were measured by perfusion manometry in fifteen patients with foreign body sensation on the pharyngoesophageal region and in twenty six controls. In upper esophageal sphincter, mean value of resting pressure of the patients by rapid pull-through technique was 45,9\ulcorner 15.6mmHg and 80.9\ulcorner9.7mmHg in the controls. The difference between the two groups was statistically significant. The distance from nostril to sphincter, length of sphincter, and resting pressure by station pull-through technique were not significantly different. The amplitude of esophageal peristalsis in the patients was reduced significantly at the level of the upper, mid and lower esophagus. The wave duration of the patients was reduced significantly at the level the upper and mid esophagus. The speed showed no difference between two groups. Length and resting pressure of lower esophageal sphincter revealed almost same values in two groups.

Keywords