Experimental Study on Boiling Heat Transfer of the Tubes with Sintered Metal Surface for Freon-11

냉매의 소결금속관 표면에서의 비등 열전달에 관한 실험적 연구

  • Published : 1981.09.01

Abstract

The purpose of this paper is to investigate the potential ability of sintered metal tube to promote heat transfer. In the experiment for Freon - 11, the boiling heat transfer on the sintered metal tube of bronze element is investigated and compared with that of the bronze tube (bare tube) atmospheric pressure. The experimental results are obtained as follows : 1) For sintered metal tubes of bronze element with particle diameters which ranges from $79({\mu})\;to\;461({\mu})$ and bare tube, boiling characteristic curves are expressed as : a) Sintered metal tube $$q{\propto}{\Delta}T^{1.05\~1.373}$$ b) Brae tube $$q{\propto}{\Delta}T^{3.096}$$ 2) Compared with that of the bare tube at low temperature difference$({\Delta}T_{sat})$, boiling heat transfer coefficient of the sintered bronze tube are relatively high. 3) There is tendency that curves of boiling heat transfer coefficients of sintered ·bronze tube and bare tube approach each other at rather high temperature difference. It is due to the increasing rate of the former heat transfer coefficient along with temperature difference is smaller than that of the latter. 4) Referring to particle diameter, optimum condition, i. e. , maximum heat transfer coefficient is found to be at approximately 2 mm thickness of sintered layer with $D_p=150({\mu})$.