Journal of Radiation Protection and Research
- Volume 1 Issue 1
- /
- Pages.22-30
- /
- 1976
- /
- 2508-1888(pISSN)
- /
- 2466-2461(eISSN)
Perturbation of Dose Distributions for Air Cavities in Tissue by High Energy Electron
고(高) 에너지 전자선(電子線) 치료시(治療時) 체내(體內) 공동(空洞)으로 인(因)한 선량분포(線量分布)의 변동(變動)
- Chu, S.S. (Department of Radiology and Nuclear Medicine, Yonsei University, College of Medicine) ;
- Lee, D.H. (Department of Radiology and Nuclear Medicine, Yonsei University, College of Medicine) ;
- Choi, B.S. (Department of Radiology and Nuclear Medicine, Yonsei University, College of Medicine)
- Published : 1976.03.25
Abstract
The perturbation of dose distribution adjacent to cavities in high energy electron has shown that the percentage of dose increase varies markedly as a function of the build-up layer, the length and thickness of the cavities, and the electron energy. The dose distribution showed that cavities similar in size to those encountered in the head and neck measured by industrial film dosimetry and corrected by ionization chambers. The most increased doses by measuring are resulted in a localized dose of up to 130% of that measured at the depth of maximum dose within a homogeneous tissue equivalent phantom. The measured values and correction factors of dose perturbation due to air cavities showed in diagrams and would be summarized as follows. 1. In
Keywords