정상인 및 각종 갑상선 질환 환자의 혈청 Thyroxine

Determination of Serum Thyroxine Levels in Normal Korean Subjects and Various Thyroid Diseases

  • 김동집 (가톨릭의과대학 내과학교실) ;
  • 민병석 (가톨릭의과대학 내과학교실) ;
  • 박용휘 (가톨릭의과대학 방사선과학교실) ;
  • 김부성 (가톨릭의과대학 내과학교실)
  • Kim, Dong-Jip (Department of Internal Medicine, Catholic Medical College) ;
  • Min, Byong-Sok (Department of Internal Medicine, Catholic Medical College) ;
  • Bahk, Yong-Whee (Department of Radiology, Catholic Medical College) ;
  • Kim, Boo-Sung (Department of Internal Medicine, Catholic Medical College)
  • 발행 : 1969.11.25

초록

The serum thyroxine levels were measured by method of Tetrasorb Kit in 69 subjects including 13 subjects in euthyroid state, 31 with hyperthyroidism, 5 with hypothyroidism, 13 with nontoxic diffuse goiter, and 7 with nontoxic nodular goiter. Three parameters of the thyroid function test including thyroxine ($T_4$) levels, $^{131}I$ uptake (24 hrs) values and $PB^{131}I$ conversion ratio were correlated with clinical manifestations and courses of the disease. 1. The serum $T_4$ levels in the normal subjects were in range of $6.0{\mu}g/dl\;to\;14.4{\mu}g/dl$. (The mean $9.4{\mu}g/dl$). 2. The diagnostic compatibility of the serum $T_4$ was 93.5% in hyperthyroidism, 100% both in hypothyroidism and in nontoxic diffuse goiter, 86% in nontoxic nodular goiter, or 95.8% in the entire series. (Table 1). 3. The diagnostic compatibility of $^{131}I$ uptake (24 hrs) values and $PB^{131}I$ conversion ratio were less than the serum $T_4$ levels as summarized in Tables 2 & 3. The serum $T_4$ determination by Tetrasorb Kit is a simple, accurate and very useful test of the thyroid function.

키워드