액체 요오드의 표면장력을 측정하기 위하여 새로운 장치를 고안하고 differential capillary rise method를 써서
The surface tension of liquid iodine was measured by differential capillary rise method at various temperatures above the melting point. A paraffin bath with mercury regulator was used to maintain constant temperature. The height of the meniscus of liquid iodine in the capillary tube was measured by a travelling microscope. The measured values of surface tensions at