방화문 내부 심재용 경량기포콘크리트의 방화성 검토

Reviewing the fireproofing of lightweight aerataed concrete for fire door interior cores

  • 발행 : 2023.11.10

초록

Fire doors installed to prevent the spread of fire in buildings are made of paper honeycomb, glass wool, and other materials. Due to their high water absorption rate, they absorb ambient moisture and degrade, and their increased weight causes them to sag internally, creating voids that can warp in the event of a fire and allow flames to pass through. To overcome these issues, research is being conducted on the physical performance of lightweight aerated concrete. However, there is a lack of research on how to ensure fire resistance. Therefore, in this study, the backside temperature of lightweight aerated concrete formulations was measured and compared and analyzied with the physical performance. Since it is difficult to achieve low density by saturation alone, aerated concrete with EPS was produced, which resulted in a density reduction of 24'26%, but the strength increase per unit cement increase was 5'25%, which tended to be lower than the formulation without EPS. The results showed that the lightweight aerated concrete with EPS was 130~140℃ lower than the lightweight aerated concrete with EPS, which is believed to be due to the melting point of EPS delayed the heat diffusion. In the future, wo plan to conduct research to identify the optimal formulation for fire door core materials by varying the amount of EPS added and using industrial by-products to increase long-term strength.

키워드

과제정보

본 논문은 2023년 중소벤처기업부 중소기업기술정보진흥원 산학연 Collabo R&D(과제번호: S3249235)의 일환으로 수행된 연구임을 밝히며 이에 감사를 드립니다.

참고문헌

  1. 환재훈. 공동주택 방화문 내화성능의 문제점 분석 및 개선방안:하자소송 판례분석을 중심으로. 중앙대학교 건설대학원 석사학위논문. 2017. p. 5-7.
  2. 홍상훈. 방화문 심재 적용을 위한 경량기포콘크리트의 물리적 성능 검토. 한국건축시공학회 봄학술발표대회 논문집. 2023. 제23권 1호. p. 111-112.
  3. 홍상훈. 굴 패각 및 폐 EPS를 사용한 경량기포 콘크리트의 내화성 및 열교 차단 성능 향상에 관한 연구. 공주대학교 일반대학원 석사학위논문. 2020. p. 5-9.