본 논문은 2021년 산업통상자원부 한국에너지기술평가원 에너지기술개발사업(과제번호: 20212010200080)의 일환으로 수행된 연구임을 밝히며 이에 감사를 드립니다.
Based on the carbonation depth measurement by the indicator for concrete collected from old structures and the quantitative analysis of Ca(OH)2 and CO2 in the carbonation section before and after the carbonation depth and in the non-carbonation section, the absorbable CO2 amount and carbonation degree measurement result is as follows 1) The carbonation depth of the 40-year-old reinforced concrete structure was measured to be about 22 mm. (basement interior wall, marble finish, strength 30MPa) 2) The amount of CO2 absorbed by the concrete was about 4.3% of the sample weight, and the carbonation degree was estimated to be about 53%.