Emission test of a domestic fabricated cathode with higher current density
- Ju, Yeong-Do ;
- Gong, Hyeong-Seop ;
- Kim, Seung-Hwan ;
- Tanwar, Anil ;
- Seok, Yeong-Eun ;
- Lee, Byeong-Jun ;
- Hong, Yong-Jun ;
- Sin, Jin-U ;
- So, Jun-Ho
- 주영도 (포항가속기연구소) ;
- 공형섭 (포항가속기연구소) ;
- 김승환 (포항가속기연구소) ;
- ;
- 석영은 (포항가속기연구소) ;
- 이병준 (포항가속기연구소) ;
- 홍용준 (국방과학연구소) ;
- 신진우 (국방과학연구소) ;
- 소준호 (국방과학연구소)
- Published : 2016.02.17
Abstract
The emission test a domestic fabricated cathode is conducted using an easy-replaceable-emitter-type test bench. A simple cylindrical button type cathode is dropped vertically into a cathode cup holder. The cathode is heated by a tungsten wire heater located around the cup holder. The cathode temperature is measured by an optical pyrometer. A high voltage pulse power supply gives the anode-cathode gap voltage up to 20 kV with the pulse width of 15 us. The emitted current from the cathode is captured at a faraday cup and is measured using current transformer and oscilloscope. The test bench is installed in the vacuum chamber with easy access door and, therefore, the cathode can be easily replaceable. We confirmed the emission current density of