A comparison of transient electromagnetic analysis and experiment result of Limeted angle torque motor

Limeted angle torgue motor의 전자기 과도해석 및 실험 결과의 비교

  • Published : 2015.07.15

Abstract

This paper present a transient experiment to verify the performance of limited angle torque motor(LATM) designed using electromagnetic transient analysis. LATM requires access to the transitional state to the torque performance evaluation. Because LATM moves the rotor using a magnetic torque generated by the interaction of the permanent magnet and the armature winding. A separate control is not applied, it is switched on at the same time under the conditions that the current applied to the armature winding. It was compared to the transient analysis of the experimental data of LATM for the verification of approach method in the transitional state.

Keywords