A Experimental Study on Thermal Performance of Insulated Forms with Different Insulating Methods at Low Temperature

저온환경하에서 단열처리 방법에 따른 단열거푸집의 열적성능에 관한 실험적 연구

  • 김목규 (한양대학교 건축시스템공학과) ;
  • 김형철 (성신양회(주) 기술연구소) ;
  • 최현국 (성신양회(주) 기술연구소) ;
  • 김재영 (성신양회(주) 기술연구소) ;
  • 문영범 (성신양회(주) 기술연구소) ;
  • 이한승 (한양대학교 ERICA캠퍼스 건축학부)
  • Published : 2015.05.28

Abstract

In this study, the experimental study on Thermal Performance of Insulated Forms with Different Insulating Methods at Low Temperature. For this study, placing insulated plywood based form between two constant temperature chamber that maintaining 10℃, decrease temperature of one chamber to -10℃ and -20℃. Each of steps, maintaining period of temperature was 1 hour. After placing the form, measure temperature of opposite side of the insulated form. As a result of experiment, temperature difference of rigid urethane was lowest.