Design study of the Vacuum system for RAON accelerator using MonteCarlo method

  • 김재홍 (기초과학연구원, 중이온가속기건설구축사업단) ;
  • 전동오 (기초과학연구원, 중이온가속기건설구축사업단)
  • 발행 : 2015.08.24

초록

The facility for RAON superconducting heavy-ion accelerator at a beam power of up to 400 kW will be produced rare isotopes with two electron cyclotron resonance (ECR) ion sources. Highly charged ions generated by the ECR ion source will be injected to a superconducting LINAC to accelerate them up to 200 MeV/u. During the acceleration of the heavy ions, a good vacuum system is required to avoid beam loss due to interaction with residual gases. Therefore ultra-high vacuum (UHV) is required to (i) limit beam losses, (ii) keep the radiation induced within safe levels, and (iii) prevent contamination of superconducting cavities by residual gas. In this work, a RAON vacuum design for all the accelerator system will be presented along with Monte Carlo simulation of vacuum levels in order to validate the vacuum hardware configuration, which is needed to meet the baseline requirements.

키워드