This paper describes combustion tuning methodology of double-swirl gas turbine combustor using six sigma tools. This methodology is consist of five steps-Define, Identify, Design, Optimize and Verify (DIDOV). First, the NOx reduction target was defined in the step design; second, the current status of the plant was diagnosed in the step of identify; third, the vital few control parameters to achieve the defined target were determined by analyzing the correlation between the control parameters and NOx emissions in the step of design; fourth, the optimum condition was derived from one of the six sigma tools in the step of optimize; finally, the optimum condition was verified by applying the condition to the gas turbine combustor in the step of verify. As a result of the suggested method, averaged NOx emissions were reduced by more than 70% and the standard deviation was improved by more than 60%. Thus, this methodology can be attributed to the efficient reduction of NOx emission with saving combustion tuning time.